Datalogic
Photoelectric Switch TL50-W-815 SV117
Rs 5,600.00
✓ GST Invoice | Global Shipping | Genuine Product
Photoelectric Switch TL50-W-815 SV117
The Datalogic TL50-W-815 SV117 is an RGB contrast sensor (photoelectric switch) from the TL50 series for reliable colour mark and registration mark detection. It reads the mark using red, green and blue emission with automatic selection, has 9 mm operating distance, PNP and NPN outputs and a compact IP67 ABS housing with M12 connector.
TL50-W-815 SV117 Key Features
- RGB emission (blue 465 nm / green 520 nm / red 630 nm) with automatic selection
- 33 µs response time, 15 kHz switching frequency
- MARK and BKGD push-button teach-in, automatic dark/light selection
- Selectable 20 ms output delay for slower PLC inputs
- 1 PNP + 1 NPN output, IP67, M12 4-pole connector
TL50-W-815 SV117 Specifications
| Model | TL50-W-815 SV117 |
| Type | RGB contrast sensor (colour mark sensor) |
| Operating distance | 9 mm (from front of optics) |
| Depth of field | ± 3 mm |
| Minimum spot size | 1.5 x 5 mm @ 9 mm |
| Emission | Blue 465 nm / Green 520 nm / Red 630 nm, automatic selection |
| Power supply | 10 … 30 V DC (Class 2, UL508) |
| Current consumption | 50 mA max. @ 24 V |
| Output | 1 PNP + 1 NPN |
| Output current | 100 mA max. |
| Response time | 33 µs |
| Switching frequency | 15 kHz |
| Delay | 0 / 20 ms selectable |
| Setting | MARK and BKGD push-buttons; automatic dark/light |
| Indicators | OUT (yellow), READY (green), DELAY (orange) |
| Operating temperature | -10 … 55 °C |
| Housing / lens | ABS / PMMA |
| Protection | IP67 |
| Connection | M12 4-pole connector |
| Weight | 90 g max. |
| ATEX | II 3G Ex nA II T6; II 3D Ex tD A22 IP67 T85°C |
Typical Applications
- Registration mark detection on packaging and form-fill-seal machines
- Print mark reading on labels, film and cartons
- Colour mark detection on reflective and coloured backgrounds
Genuine Datalogic (Datasensing) product supplied across India with GST invoice. The sensor is not a safety device and must not be used for machine safety functions.