Unison 803 Slim Solid State Relay: More Heater Zones in Less Panel
When a panel has twenty heater zones, every millimetre of DIN rail counts.
The Unison 803 is a slim, 23.6 mm wide zero-cross SSR that mounts straight on a 35 mm DIN rail with its own heat sink. It switches the same heater loads as a 45 mm relay but lets you fit roughly twice as many channels in a row β ideal for extruders, hot-runner controllers and multi-zone ovens.
803 Specifications
| Parameter | Value |
|---|---|
| Width Γ height | 23.6 mm Γ 44 mm (relay module) |
| Mounting | 35 mm DIN rail with matched heat sink |
| Control input | 4β32 VDC, 4β16 mA, LED indication |
| Output (48 code) | 24β480 VAC, 47β63 Hz |
| Output (58 code) | 24β580 VAC, 47β63 Hz |
| Peak inverse voltage | 800 V (25/40 A) Β· 1400 V (50/90 A) |
| Isolation | 4 kV body Β· 6β8 kV input to output |
| Protection | Built-in snubber and TVS surge suppression |
| Switching | Zero-cross |
From the Unison 803 specification sheet.
How Much Current an 803 Carries
| 803 model | Heat sink | Continuous current at 40 Β°C |
|---|---|---|
| 25 A | V-87 | about 18 A |
| 40 A | V-87 / B-24 | about 20 A / 30 A |
| 50 A | B-72 | up to about 40 A |
| 90 A | B-72 | up to about 60 A |
Per Unisonβs data at 40 Β°C panel air. Hotter panels need more margin or forced ventilation.
Why Panel Builders Choose the 803
Half the rail
Ten 45 mm relays need about 450 mm of rail; ten 803s need about 236 mm. That can save a whole panel size.
580 VAC headroom
The 58-code 803 has 1400 V peak inverse voltage, giving margin on 415 V lines with spikes from long cables and contactors.
Rail-mount service
Clip on, clip off. No drilling a back plate for each heat sink, and wiring stays in neat rows.
Unison 803 in Stock
Mounting Tips for Slim SSRs
- Keep them vertical. Fins must run up and down so hot air rises through them.
- Mind the neighbours. Slim relays mounted side by side heat each other; above about 60 % of rating, leave a gap or add a panel fan.
- Check panel air temperature. Ratings are at 40 Β°C. In a 50 Β°C panel, reduce current or move to the next heat sink size.
- Tighten terminals properly. Loose load terminals are the most common cause of burnt SSRs β re-torque after the first heat cycles.
- Choose 58-code on 415 V. Use the 580 V version on phase-to-phase 415 V loads for extra voltage margin.
Unison 803 Slim SSR FAQs
How wide is the Unison 803?
The relay is 23.6 mm wide, about half the width of a standard 45 mm SSR.
What is the difference between 803 ZDA 48 and 803 ZDA 58?
48 versions switch 24β480 VAC; 58 versions switch 24β580 VAC with a higher 1400 V peak inverse rating.
Does the 803 need a separate heat sink?
It mounts on a matched DIN-rail heat sink. The heat sink size decides the continuous current.
Can the 803 be driven by a temperature controller?
Yes. Any controller with an SSR drive (voltage pulse) output of 4β32 VDC can drive it directly.
Is the 803 suitable for motors?
It is a zero-cross relay intended for heaters and resistive loads. For motors, use a relay rated for inductive loads with generous current margin.
Do you stock the 50 A slim version?
Yes, the 803 ZDA 58 50 01 is in stock with same-day dispatch.
Plan a Slim SSR Panel
Send us the number of zones, heater power per zone, supply voltage and panel size. We will suggest the 803 model, heat sink and layout.
Office Address
F412 (4th floor), Plot No-21, Arthamart, Techzone-4, Noida Extension, UP β 201318
By appointment only
π Quick Enquiry
Reply within business hours on WhatsApp and email.
β‘ Prefer Quick Phone Consultation?
Call our application engineers directly for immediate assistance and personalised recommendations. Office Time: 10:00 AM β 6:00 PM (MonβSat).
π Call Sales: +91 99530 39482 π Support: +91 99530 39482